Step 1 — The Bill-to-kW Formula
Every solar sizing calculation starts with one number: your monthly electricity consumption in kWh. Your DISCO bill shows this. If you cannot find it, divide your bill amount by your average per-unit rate.
| Your Monthly Bill (PKR) | Est. Units (kWh) | Recommended System | On-Grid Price | Detailed Guide |
|---|---|---|---|---|
| Rs 3,000 – Rs 7,000 | 100–200 | 3kW | Rs 380,000 | Read → |
| Rs 7,000 – Rs 15,000 | 200–430 | 5kW | Rs 650,000 | Read → |
| Rs 12,000 – Rs 20,000 | 350–570 | 6kW | Rs 750,000 | Read → |
| Rs 18,000 – Rs 28,000 | 500–800 | 8kW | Rs 900,000 | Read → |
| Rs 25,000 – Rs 40,000 | 700–1,150 | 10kW | Rs 1,100,000 | Read → |
| Rs 35,000 – Rs 60,000 | 1,000–1,700 | 15kW | Rs 1,500,000 | Read → |
| Rs 50,000 – Rs 80,000 | 1,400–2,300 | 20kW | Rs 1,900,000 | Read → |
| Rs 70,000 – Rs 110,000 | 2,000–3,100 | 25kW | Rs 2,300,000 | Read → |
| Rs 90,000 – Rs 150,000 | 2,600–4,300 | 30kW | Rs 2,700,000 | Read → |
| Rs 150,000+ | 4,300+ | 50kW | Rs 4,200,000 | Read → |
This table gives you the starting point. But the formula has three adjustments that make it precise — and skipping them is how buyers end up with undersized or oversized systems.
Don't want to do the maths? Send us a photo of your latest electricity bill — we'll calculate your exact size for free.
💬 Send My Bill for Free SizingStep 2 — Adjust for Seasonal Variation
Most buyers look at their summer bill (the highest) and size for that. This is a mistake — or a deliberate choice, depending on your priorities.
| Season | Typical Bill (medium home) | Solar Output (per kW installed) | Net Effect |
|---|---|---|---|
| Summer (Apr–Sep) | Rs 25,000–40,000 | 130–150 kWh/kW/month | Higher consumption BUT higher production |
| Winter (Nov–Jan) | Rs 8,000–15,000 | 90–110 kWh/kW/month | Lower consumption AND lower production |
| Shoulder (Feb–Mar, Oct) | Rs 12,000–20,000 | 110–130 kWh/kW/month | Balanced |
The right approach: Size your system for your annual average consumption, not your summer peak. If your summer bill is Rs 35,000 and your winter bill is Rs 12,000, your average is roughly Rs 23,500 — that points to a 6kW system, not the 10kW your summer bill suggests. With net metering, surplus summer generation credits your winter consumption — the system balances across the year.
Step 3 — Account for Future Load Growth
Your electricity consumption is not static. Are you planning to add air conditioning, an electric vehicle charger, or a home office? Will your family grow? These additions increase your load — and if your system is already at capacity, you cannot expand without adding more panels and potentially upgrading your inverter.
Our rule of thumb: Add 10–20% to your calculated size for residential, 5–10% for commercial (commercial loads are more predictable). A household that calculates at 5kW should consider a 6kW system — the Rs 100,000 premium buys you headroom that would cost Rs 200,000+ to retrofit later.
The smart trick: Even if you cannot afford the extra panels today, install a hybrid inverter rated one size up. A 10kW inverter with 8kW of panels works perfectly — and when you are ready to add panels, you simply wire them in without replacing the inverter. This costs Rs 15,000–25,000 more upfront versus replacing a maxed-out inverter later at Rs 90,000–175,000.
5 Sizing Mistakes That Cost Pakistani Buyers Thousands
Mistake 1 — Sizing by appliance count instead of bill: "I have 3 ACs, 2 fridges, and 10 fans — what size do I need?" is the wrong question. AC usage varies wildly — are they running 2 hours or 16 hours daily? Your bill integrates all these variables into one number. Always start with the bill.
Mistake 2 — Ignoring the tariff slab effect: Pakistan's residential tariff is progressive — higher slabs cost more per unit. A 10kW system that eliminates your top slab saves more per kWh than the first slab you would have paid. This means solar saves more per unit than your average bill rate — your ROI is better than a simple bill ÷ tariff calculation suggests.
Mistake 3 — Forgetting roof orientation and shading: A south-facing roof in Lahore produces ~15% more than a west-facing roof. A partially shaded roof loses 10–30% of potential output. If your roof faces east or has significant afternoon shading, you may need a system one size larger than the bill calculation suggests. Send photos of your roof and we'll assess remotely.
Mistake 4 — Choosing hybrid when on-grid is enough: A hybrid system costs 27–47% more than on-grid for the same solar capacity. That premium buys battery backup, not more kW. If you need 10kW of solar production, both on-grid and hybrid 10kW systems produce the same amount — the hybrid just costs Rs 400,000 more. Do not confuse system type with system size.
Mistake 5 — Undersizing to save money: A 3kW system that covers 50% of your bill has a longer payback than a 5kW system that covers 100% — because the 5kW system eliminates your highest tariff slabs. The per-watt cost also drops at larger sizes (Rs 130/W at 3kW vs Rs 110/W at 10kW). Undersizing saves money upfront but costs more over the system's lifetime.
Residential vs Commercial — Different Sizing Rules
| Factor | Residential (3–10kW) | Commercial (15–50kW) |
|---|---|---|
| Primary Goal | Eliminate bill | Reduce operating costs |
| Sizing Basis | Annual average bill | Daytime load profile |
| Growth Buffer | +10–20% | +5–10% |
| Net Metering Cap | 25kW (most DISCOs) | Separate commercial track |
| Tariff Advantage | Eliminates top slabs first | Flat commercial rate — every unit saves equally |
| Best System Type | On-grid (unless 4+ hrs load-shedding) | On-grid (daytime loads match solar output) |
| Typical Payback | 16–24 months | 12–20 months |
Commercial systems have faster payback because commercial tariff rates (Rs 32–48/unit) are higher than residential average rates, and daytime consumption naturally aligns with solar production hours. If you run a factory, shop, or office, your solar system works hardest during the exact hours you need it most.
The Complete Sizing Cheat Sheet — All 10 Sizes
Here is the definitive reference — every system size Enon Traders installs with monthly output, panel count, and the full price comparison (on-grid vs hybrid).
| Size | Panels | Monthly Output | On-Grid | Hybrid | Best For |
|---|---|---|---|---|---|
| 3kW | 6 | ~360 kWh | Rs 380K | Rs 510K | Small homes, 1–2 AC |
| 5kW | 9 | ~600 kWh | Rs 650K | Rs 850K | Medium homes, 2–3 AC |
| 6kW | 11 | ~720 kWh | Rs 750K | Rs 950K | Large homes, buffer for growth |
| 8kW | 15 | ~960 kWh | Rs 900K | Rs 1,150K | Villas, small offices |
| 10kW | 18 | ~1,200 kWh | Rs 1,100K | Rs 1,500K | Large homes, shops |
| 15kW | 27 | ~1,800 kWh | Rs 1,500K | Rs 2,200K | Showrooms, clinics |
| 20kW | 36 | ~2,400 kWh | Rs 1,900K | Rs 2,800K | Small factories |
| 25kW | 45 | ~3,000 kWh | Rs 2,300K | Rs 3,200K | Medium commercial |
| 30kW | 55 | ~3,600 kWh | Rs 2,700K | Rs 3,800K | Factories, tube wells |
| 50kW | 91 | ~6,000 kWh | Rs 4,200K | Rs 5,800K | Industrial, large commercial |
Pakistan's 3 Most Popular System Sizes — August 2026
🏠 5kW — Most Popular Home
- 9 × Tier-1 panels
- ~600 kWh/month
- Covers Rs 10K–18K bill
- Payback: 16–22 months
🏢 10kW — Crossover Favourite
- 18 × Tier-1 panels
- ~1,200 kWh/month
- Covers Rs 25K–40K bill
- Payback: 14–20 months
🏭 20kW — Commercial Sweet Spot
- 36 × Tier-1 panels
- ~2,400 kWh/month
- Covers Rs 50K–80K bill
- Payback: 12–18 months
The Simple Answer
Annual average bill ÷ per-unit rate ÷ 120 = your kW size. Add 10–20% for residential growth. Round up to the nearest standard size (3, 5, 6, 8, 10, 15, 20, 25, 30, or 50kW). Choose on-grid unless you get 4+ hours of load-shedding. Pair with Tier-1 panels and a reliable inverter. That is the whole formula. If you want someone to do it for you, WhatsApp us your bill — we've done this 2000+ times.
Frequently Asked Questions — Solar System Sizing
A Rs 20,000 monthly bill typically means 550–600 kWh consumption. A 5kW or 6kW on-grid system covers this completely. We recommend 6kW (Rs 750,000) to allow for future growth. Payback: 16–22 months.
Slightly — 10–20% above your annual average consumption is optimal. This covers growth without wasting investment. Oversizing beyond 20% is wasteful with net metering because your DISCO credits surplus but does not pay cash for excess generation.
Yes, if you plan ahead. Install a hybrid inverter rated one size above your current panels. A 10kW inverter with 6kW of panels today can expand to 10kW of panels later — just add 7 more panels and rewire. This costs Rs 15–25K more upfront vs replacing a maxed-out inverter at Rs 90–175K.
Divide your system kW by your panel wattage. A 10kW system with 550W panels needs 18 panels. A 5kW system needs 9 panels. See the sizing cheat sheet above for every size.
📋 Update Log
- 26 Aug 2026: Initial publish — sizing formula and tables verified against Enon Traders installation data.
Trusted by 2000+ Installations Across Pakistan
Enon Traders — we size your system to your bill, not to our margins. Free sizing for every inquiry.